Whirlpool Ventilation Hood GZ7930XG User Manual

®
Retractable Downdraft Vent System  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
GZ7930XG  
GZ7930XH  
GZ7936XG  
GZ7936XH  
top trim widths  
30" vent (76.2 cm)  
36" vent (91.4 cm)  
Electrical: 120-volt, 60-Hz, AC-only, 15 amp  
electrical supply. Use copper wire only. A time-  
delay fuse or circuit breaker and separate circuit is  
recommended.  
8-1/4" (21 cm)  
retractable  
vent height  
1-1/2"  
(3.8 cm)  
4"  
3/8" (9.5 mm)  
27" (68.6 cm) for 30" (76.2 cm) vent  
33" (83.8 cm) for 36" (91.4 cm) vent  
(10.2 cm)  
16"  
(40.6 cm)  
26-1/8"  
(66.4 cm)  
8"  
EXTERIOR-MOUNTED  
(20.3 cm)  
3-1/4"x 10"  
(8.3 cm x 25.4 cm)  
BLOWER MOTOR  
For use with  
Model No. KPEC992M  
[900 cfm (25.5 m3/m)]  
only  
16"  
(40.6 cm)  
5/8"  
(15.9 mm)  
9" (22.9 cm)  
Diameter  
5/8"  
(15.9 mm)  
INTERNAL  
BLOWER  
16"  
8"  
(20,3 cm)  
(40.6 cm) MOTOR  
2-1/8”  
(54 cm)  
16"  
(40.6 cm)  
9-3/8"  
(23.8 cm)  
CABINET OPENING DIMENSIONS  
See cooktop manufacturers  
instructions for cooktop cutout  
depth and width.  
Maximum length of vent system  
Vent Length  
Use dimensions for vent system  
cutout location that applies to  
your installation.  
4-1/8"+A  
(10.5 cm)  
6" (15.2 cm) round 35 feet (8.9 m)  
3-1/4" x 10"  
35 feet (8.9 m)  
(8.3 cm x 25.4 cm)  
A = 1/2" (12.7 mm)  
min.  
For best performance, use no more than  
three 90° elbows. If more than one elbow  
is used, make sure that there is a  
minimum of 24" (61 cm) of straight vent  
between any two elbows. Do Not install  
two elbows together. It is recommended  
that you use round vent instead of  
23-9/16"  
(59.8 cm)  
17-9/16"  
(44.6 cm)  
17-3/16"  
(43.7 cm)  
rectangular vent, especially if elbows are  
required. If rectangular vent is required,  
it should be transitioned to 6" (15.2 cm)  
round vent as soon as possible.  
all cutouts shown are  
for 3-1/4" x 10"  
(8.3 cm x 25.4 cm)  
vent system  
3/8"  
(9.5 mm)  
Determining the length of system  
you need:  
To calculate the length of system you  
need, add the equivalent feet for each  
vent piece that will be needed. See  
example for 6" (15.2 cm) round vent  
system.  
Locate power supply  
junction box at lower  
right hand rear corner of  
cabinet.  
centerline of  
cooktop cutout  
Vent system cutout dimensions for internal blower models only.  
Exterior mounted blower systems connect with 10" (25.4 cm) round vent.The cutout  
locations for this vent system will depend upon your specific installation.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8284826 Rev. B  
10-20-03  
 

West Bend Popcorn Poppers 82386 User Manual
Westinghouse Juicer 1099315 User Manual
Whirlpool Air Conditioner ACE184XM0 User Manual
Whirlpool Range YIES366RS2 User Manual
Woods Equipment Lawn Mower FSW6000F User Manual
Yamaha DJ Equipment M7CL User Manual
Yamaha Guitar APX 5 12A User Manual
Zanussi Oven 237000 User Manual
Zanussi Refrigerator 102258 User Manual
Zanussi Washer ZWV 1651S User Manual