RMM Rack Mount Modem; User's Guide
WTI Part No.: 12548
Rev. F
RMM
Rack Mount Data/Fax Modem
User's Guide
5 Sterling, Irvine, California 92618-2517
U.S. and Canada: 1-800-854-7226
Phone: (949) 586-9950
Fax: (949) 583-9514
Table of Contents
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (1 of 21) [2/7/2000 10:55:42 AM]
RMM Rack Mount Modem; User's Guide
Answer mode only: Modem is answering a call and
DIP Switch 5 is UP (Enable Auto Answer), or register
S0 is set to 1 (Auto Answer, 1 Ring).
AA
On
(Auto Answer)
Off No activity, or modem is originating a call.
Flash Incoming call.
A valid data carrier signal has been received from a
remote modem, and Dip Switch 6 is UP (Normal
Carrier Detect). Modem is ready to transmit data.
The CD Indicator will remain ON constantly if Dip
Switch 6 is DOWN (Carrier Detect Override).
CD
On
(Carrier Detect)
RD
Modem is sending result codes or passing received
data bits.
Flash
(Receive Data)
SD
(Send Data)
Flash Computer is sending data bits.
Modem is receiving DTR signal from computer. The
TR indicator will only function when Dip Switch 1 is
UP (Normal DTR). Remains ON constantly if Dip
Switch 1 is DOWN (DTR Override).
TR
(Data Terminal
Ready)
On
CS
Hardware flow control is enabled (&H1, &H3),
modem is waiting for low CTS signal.
On
(Clear to Send)
3. Operation
The following commands can be used to display current configuration status and various help menus:
ATI4
AT$
View Modem Setup:
Basic Help Menu:
ATD$
AT&$
ATS$
ATZ3
Dial Command Help Menu:
Configuration Command Help Menu:
List of S-Registers:
Reset Modem to Default Profile 0:
When the View Modem Setup command (ATI4) is invoked, the RMM will display a status screen as
shown below.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (3 of 21) [2/7/2000 10:55:42 AM]
RMM Rack Mount Modem; User's Guide
B0 E1 F1 M1 Q0 V1 X1 Y0
BAUD=9600 PARITY=N WORDLEN=8
DIAL=PULSE ON HOOK
&A1 &B0 &C1 &D2 &G0 &H0 &I0 &K1
&M4 &N0 &P0 &R1 &S0 &T5 &Y1
S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002
S07=060 S08=002 S09=006 S10=007 S11=070 S12=050 S13=000
S14=000 S15=000 S16=000 S17=000 S18=000 S19=000 S20=000
S21=010 S22=017 S23=019 S24=000 S25=005 S26=000 S27=000
S28=008 S29=020 S30=000 S31=000 S32=000 S33=000 S34=006
S35=000 S36=014 S37=000 S38=000 S44=015 S51=000
Figure 2: The Status Screen (Defaults Shown)
4. Installation
4.1. 48 Volt DC Power Option
The 48 Volt DC input is not polarity sensitive. Therefore, you can connect either positive or negative
wires from your 48 volt power source to either input and the internal circuitry will adjust for the proper
polarity.
Input Range: 40 - 60 Volts DC, 200 milliamps maximum.
Figure 3: 48 Volt DC Power Option
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (4 of 21) [2/7/2000 10:55:42 AM]
RMM Rack Mount Modem; User's Guide
4.2. Dip Switch Settings
Factory
Setting
Switch
Function
1
Data Terminal Ready (DTR) Override
Normal DTR operations: Computer must provide
X
UP
DTR signal for modem to accept commands.
Dropping DTR terminates call.
DOWN DTR Override: Modem ignores DTR
2
3
4
5
Verbal/Numeric Result Codes
X
UP
Verbal (Word) Results
DOWN Numeric Results
Result Code Display
UP
Suppress Result Codes
X
X
DOWN Display Result Codes
Command Mode Local Echo Suppression
UP
Enable Echo
DOWN Suppress Echo
Auto Answer Suppression
Auto Answer On: Modem answers on first ring, or
higher if specified in NVRAM
X
X
UP
DOWN Auto Answer Off: Disable auto answer
6
7
Carrier Detect (CD) Override
Normal: Modem sends CD signal when connecting
with another modem, drops CD on disconnect
UP
DOWN Override: CD always ON
Power-On and ATZ Reset Software Defaults
User Defaults: Load Y or Y1 configuration from
user-defined nonvolatile memory (NVRAM).
UP
Factory Defaults; Load &F0 (Generic) template
DOWN
X
from read-only memory (ROM).
8
AT Command Set Recognition
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (5 of 21) [2/7/2000 10:55:42 AM]
RMM Rack Mount Modem; User's Guide
UP
Dumb Mode: Disables command recognition
X
DOWN Smart Mode: Enables command recognition
5. Command Summary
● Type commands in either upper or lower case. Do not use a combination of upper and
lower case characters.
● Use the Backspace key to delete errors. Note that the original AT command is stored
in the modem buffer, and cannot be deleted.
● Some commands have numeric options. If these commands are invoked without a
numeric option, the modem will assume option 0 (zero). For example, when the
command ATBis invoked, the modem will assume command ATB0was intended.
● All commands begin with the AT prefix, and are invoked by pressing [Enter]
(Carriage Return). The only exceptions are the A/command (Repeat previous
command) and +++(Exit to on-line command mode).
● The maximum command length is 40 characters. This does not include the ATprefix,
Carriage Returns, or spaces.
Note: Default values are marked with an asterisk. All defaults are based on the
&F1-Hardware Flow Control Template loaded in NVRAM.
Command Function/Options
$
Displays basic command list (On-line Help Menu).
A
Manual Answer: goes off hook in answer mode. Pressing any key aborts the
operation.
A/
Re-executes the last issued command. Used mainly to redial. Does not require
the AT prefix or a Carriage Return.
Any Key Aborts off-hook dial/answer operation and hangs up.
AT
Required prefix for all modem commands. Can also be used to test for the OK
result code. Not required for the A/ command or +++ command.
Bn
U.S./ ITU-T answer sequence
* B0 ITU-T answer sequence
B1 U.S. answer tone
Dn
Dials the specified phone number. Can also include the following command
options:
DL Re-dials last number dialed
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (6 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
* DP Pulse (Rotary) Dial Mode
DR Originates call using answer (reverse) frequencies.
DSn Dials phone number string stored in NVRAM at position n (n = 0-3).
Phone numbers are stored with the &Zn=s command.
DT Tone Dial Mode
D, (Comma) Two Second Pause. Comma pause duration can be
redefined via the S8 Register.
D; (Semicolon) Return to Command Mode after dialing.
D" Dials the letters that follow (in an alphabetic number).
D! (Exclamation Point) Flashes the switch hook.
D/ Delays for 125 msec before proceeding with dial string.
DW Wait for second dial tone (X3 or higher). Linked to S6 Register.
D@ Dials, waits for 5 seconds of silence after detecting ringbacks, and
then continues (X2 or X4).
D$ Displays a list of dial commands.
Sets local echo. (Also controlled by DIP Switch 4).
E0 Echo Off
En
Fn
* E1 Modem displays keyboard commands.
Sets online local echo of transmitted data On/Off.
F0 Local echo ON. Modem sends a copy of data it sends to the remote
system to your screen.
* F1 Local echo OFF. Receiving system may send a remote echo of data it
receives.
Hn
In
Controls On/Off Hook
H0 Hangs up (goes on hook)
H1 Goes off hook
Displays the following information:
I0 Four-digit product code
I1 Results of ROM checksum
I2 Results of RAM checksum
I3 Product type
I4 Current modem settings
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (7 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
I5 Nonvolatile memory (NVRAM) settings
I6 Link diagnostics
I7 Product configuration
Mn
On
Operates Speaker
M0 Speaker always Off.
* M1 Speaker On until connect.
M2 Speaker always On.
M3 Speaker On after dial, until connect.
Returns online
O0 Returns online.
* O1 Returns online and retrains.
Sets pulse dial (for phone lines that don't support touch-tone dialing).
Displays/suppresses result codes. Also controlled by DIP switch 3.
* Q0 Displays result codes.
Q1 Quiet mode; no result codes.
P
Qn
Q2 Displays result codes only in Originate mode. Cannot be stored in
NVRAM.
Sr.b=n
Sr=n
Sr?
Sets bit .b of register r to value n (0 = OFF or 1 = On)
Sets register r to value n. See list of S-Register settings.
Displays contents of S-Register r.
T
Sets tone dial.
Vn
Displays verbal/numeric result codes. Also controlled by DIP switch 2
V0 Numeric codes.
* V1 Verbal codes.
Command Function/Options
Xn Sets result code displayed. The default is X4.
Xn Setting
Result Codes
X0 X1 X2 X3 X4
0/OK
X
X
X
X
X
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (8 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
1/CONNECT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2/RING
3/NO CARRIER
4/ERROR
5/CONNECT 1200
6/NO DIAL TONE
7/BUSY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8/NO ANSWER*
10/CONNECT 2400
13/CONNECT 9600
18/CONNECT 4800
20/CONNECT 7200
21/CONNECT 12000
25/CONNECT 14400
43/CONNECT 16800
85/CONNECT 19200
91/CONNECT 21600
99/CONNECT 24000
103/CONNECT 26400
107/CONNECT 28800
151/CONNECT 31200
155/CONNECT 33600
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Functions
Adaptive Dialing
Wait for 2nd Dial Tone (W)
Wait for Answer (@)
Fast Dial
X
X
X
X
X
X
X
X
X
* Requires @ in dial string; replaces NO CARRIER
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (9 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
Command Function/Options
Yn
Selects Power-on/Reset default configuration.
* Y0 Default is profile 0 setting in NVRAM.
Y1 Default is profile 1 setting in NVRAM.
Resets modem based on current DIP Switch settings.
Z0 Resets modem to NVRAM profile selected by the Y command.
Z1 Resets modem to NVRAM profile 0.
Zn
Z2 Resets modem to NVRAM profile 1.
Z3 Resets modem to factory default profile 0 (&F0).
Z4 Resets modem to factory default profile 1 (&F1).
Z5 Resets modem to factory default profile 2 (&F2).
Displays a list of ampersand (&) commands.
Enables/disables additional result code subsets (see Xn).
&A0 ARQ result codes disabled.
&$
&An
&A1 ARQ result codes enabled.
&A2 V.32 modulation indicator added.
* &A3 Protocol indicators added - LAPM/MNP/NONE (error control) and
V42BIS/MNP5 (data compression).
&Bn
Manages modem's serial port rate.
&B0 Variable, follows connection rate.
* &B1 Fixed Serial port rate.
&B2 Fixed in ARQ mode, variable in non-ARQ mode.
Controls Carrier Detect (CD) signal.
&C0 CD override
&Cn
&Dn
* &C1 Normal CD operations
Controls Data Terminal Ready (DTR) operations. Also controlled by DIP
Switch 1.
&D0 DTR override
&D1 DTR toggle causes online Command Mode.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (10 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
* &D2 Normal DTR operations
&D3 Resets on receipt of DTR
&Fn
&Gn
&Hn
Loads a read-only (non-programmable) factory configuration.
&F0 Generic Template
* &F1 Hardware flow control template
&F2 Software flow control template
Sets Guard Tone
* &G0 No guard tone (U.S.A. and Canada).
&G1 550 Hz guard tone (some European countries); requires B0 setting.
&G2 1800 Hz guard tone (U.K.); requires B0 setting.
Sets Transmit Data (TD) flow control.
&H0 Flow control disabled.
* &H1 Hardware flow control, Clear to Send (CTS).
&H2 Software flow control, XON/XOFF.
&H3 Hardware and Software flow control.
Sets Receive Data (RD) software flow control (see also &Rn).
* &I0 Software flow control disabled.
&I1 XON/XOFF signals to your modem and remote system.
&I2 XON/XOFF signals to your modem only.
Enables/disables data compression.
&In
&Kn
&K0 Data compression disabled
* &K1 Auto enable/disable
&K2 Data compression enabled
&K3 MNP5 compression disabled
&Mn
Sets Error Control (ARQ for connection at 1200 bps and higher.
&M0 Normal mode, error control disabled
&M1 Reserved
&M2 Reserved
&M3 Reserved
* &M4 Normal/ARQ
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (11 of 21) [2/7/2000 10:55:43 AM]
RMM Rack Mount Modem; User's Guide
&M5 ARQ mode
&Nn
Sets connect speed. If connection cannot be established at this speed, the
modem will hang up. Sets ceiling connect speed if &Un is greater than 0 (See
&Un).
* &N0 Variable Rate
&N1 300 bps
&N2 1200 bps
&N3 2400 bps
&N4 4800 bps
&N5 7200 bps
&N6 9600 bps
&N7 12,000 bps
&N8 14,400 bps
&N9 16,800 bps
&N10 19,200 bps
&N11 24,000 bps
&N12 24,000 bps
&N13 26,400 bps
&N14 28,800 bps
&N15 31,200 bps
&N16 33,600 bps
&Pn
&Rn
Sets pulse (rotary) dial make/break ratio.
* &P0 U.S.A./Canada ratio; 39%/61%
&P1 U.K. ratio; 33%/67%
Sets Receive Data (RD) hardware flow control, Request to Send (RTS) (See
also &In).
&R0 Reserved
* &R1 Modem ignores RTS
&R2 Received Data to computer
Controls Data Set Ready (DSR) operations.
* &S0 DSR override; always ON
&Sn
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (12 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
&S1 Modem controls DSR
&Tn
Begins test modes
&T0 Ends test in progress
&T1 Analog Loopback
&T2 Reserved
&T3 Local Digital Loopback
&T4 Enables Remote Digital Loopback
* &T5 Prohibits Remote Digital Loopback
&T6 Initiates Remote Digital Loopback
&T7 Remote Digital with self test and error detector
&T8 Analog Loopback with self test and error detector
&Un
Sets floor connect speed when &Un is greater than 0 (zero). &Nn is the
ceiling connect speed (See also &Nn).
* &U0 Disabled
&U1 300 bps
&U2 1200 bps
&U3 2400 bps
&U4 4800 bps
&U5 7200 bps
&U6 9600 bps
&U7 12,000 bps
&U8 14,400 bps
&U9 16,800 bps
&U10 19,200 bps
&U11 21,600 bps
&U12 24,000 bps
&U13 26,400 bps
&U14 28,800 bps
&U15 31,200 bps
&U16 33,600 bps
Writes current configuration to NVRAM templates.
&Wn
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (13 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
&W0 Modifies the NVRAM 0 template (Y0).
&W1 Modifies the NVRAM 1 template (Y1).
Sets break handling
&Yn
&Y0 Destructive, but doesn't send break.
* &Y1 Destructive, expedited
&Y2 Non-destructive, expedited
&Zn=s
Writes phone number s to NVRAM at position n (n = 0 - 3).
&Zn=L Writes the last executed dial string to NVRAM at position n (n = 0 - 3).
&Zn?
&ZL?
+++
Displays the phone number stored at position n (n = 0 - 3).
Displays the last executed dial string.
Escapes to online Command Mode.
6. S-Registers
Note: To change a setting, use the ATSr=n command, where r is the register and n is a
decimal value from zero to 255 (unless otherwise indicated).
Register Default Function
S0
1
Sets the number of rings on which to answer in Auto Answer mode.
When set to 0 (zero), Auto Answer is disabled. Auto Answer is also
controlled by DIP Switch 5.
S1
S2
0
Counts and stores the number of rings from an incoming call. Register
S0 must be greater than 0.
43
Stores the ASCII decimal code for the escape code character. The
default character is +. Any value between 128 and 255 will disable the
escape code.
S3
S4
S5
13
10
8
Stores the ASCII code for the Carriage Return character. Valid range
is 0 to 127.
Stores the ASCII decimal code for the Line Feed character. Valid
range is 0 to 127
Stores the ASCII decimal code for the Backspace character. Any value
between 128 and 255 will disable the Backspace key's delete function.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (14 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
S6
2
Sets the number of seconds the modem will wait before dialing. If Xn
is set to X2 or X4, S6 determines the timeout length when no dial tone
is detected.
S7
60
Sets the number of seconds the modem will wait for a carrier. Often
used to select a longer duration when the modem is originating an
international connection.
S8
S9
2
6
Sets the duration (in seconds) for the Dial command pause option (,).
Determines the length of time (in tenths of a second) the remote
modem's carrier signal must continue in order to be recognized by the
RMM.
S10
7
Sets the length of time (in tenths of a second) the modem will wait
after loss of carrier before hanging up. Allows the modem to
distinguish between a line hit (or other momentary break) from a true
disconnect (hang up) by the remote modem.
Although it is not recommended to connect to a line with call waiting,
the S10 register can be adjusted upward to prevent the modem from
misinterpreting the second call signal as a remote disconnect. If call
waiting is a problem, it is preferable to contact your phone company to
determine the command to temporarily disable call waiting (typically
*70W). For example: ATDT *70W phone number.
Note: If S10 = 255, the modem will not hang up when the carrier is
lost. Dropping DTR hangs up the modem.
S11
S12
70
50
Sets the duration and spacing (in milliseconds) for tone dialing.
Sets the duration (in fiftieths of a second) of the guard time for the
escape code sequence (+++).
S13
0
Bit-mapped register. Select the bit(s) you want ON and set S13 to the
total of the values in the Value Column. For example, ATS13=17
enables bit 0 (value is 1) and bit 4 (value is 16).
Bit
0
Value
Result
1
2
Reset when DTR drops.
1
Reset non-MNP transmit buffer from 1.5K
to 128 bytes*
2
3
4
8
Set Backspace key to delete.
On DTR signal, autodial the number stored
in NVRAM at position 0.
4
16
At Power-On/Reset, autodial the number
stored in NVRAM at position 0.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (15 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
5
6
7
32
64
Reserved
Reserved
128
Disconnect on escape code.
* The 1.5K-byte non-ARQ buffer allows data transfer with Xmodem
and Ymodem type file transfer protocols without using flow control.
The 128 Byte option allows remote users with slower modems to
prevent transmitted data from scrolling off screen. When a remote user
sends an XOFF (Ctrl-S) to your computer and transmission stops, data
in transit from your modem's buffer does not exceed the size of the
remote user's screen. This is also helpful when a remote
modem/printer application is losing characters.
S14
S15
0
0
Reserved
Bit-mapped register setup. To set the register, see instructions for S13.
Bit
0
Value
Result
1
2
4
Disable ARQ/MNP for V.22.
Disable ARQ/MNP for .22 bis.
1
2
Disable ARQ/MNP for V.32 / V.32bis /
V.32terbo.
3
4
5
6
7
8
16
32
64
128
Disable MNP handshake.
Disable MNP level 4.
Disable MNP level 3.
MNP incompatibility.
Disable V.42 operation.
S16
S17
0
0
Bit-mapped register setup. To set the register, see instructions for S13.
Bit
Value
---
Result
0
1
Reserved
2
Touch tone dialing test.
Reserved
2 - 7
Reserved
---
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (16 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
S18
0
Test timer for &Tn loopback testing. Sets the length of time (in
seconds) the modem will wait before automatically timing out and
terminating the test. When set to 0, the timer is disabled. Valid range
is 1 - 255.
S19
0
Sets the duration (in minutes) for the Inactivity Timer. The timer
activates when there is no data activity on the phone line. At time out,
the modem hangs up. S19 = 0 disables the timer.
S20
S21
0
Reserved
10
Sets the length (in 10 millisecond units) of Breaks sent from the
modem to the computer. Applies to MNP or V.42 mode only.
S22
S23
S24
S25
17
19
0
Stores the ASCII decimal code for the XON character.
Stores the ASCII decimal code for the XOFF character.
Reserved
5
Sets the duration (in hundredths of a second) that DTR must be
dropped in order to be interpreted as a DTR loss. Allows the modem
to differentiate between a random glitch and a true DTR loss.
In most cases, the default value can be used. The S25 register is useful
for setting compatibility with older systems running under older
operating software.
S26
S27
0
0
Reserved
Bit mapped register setup. To set the register, see the instructions for
S13.
Bit
Value
Result
0
1
Enables ITU-T V.21 modulation at 300 bps
for overseas calls; in V.21 mode, the
modem answers both overseas and
domestic (U.S. And Canada) calls, but only
originates V.21 calls (Default Bell 103).
1
2
Enables un-encoded (non-trellis coded)
modulation in V.32 mode.
2
3
4
8
Disables V.32 modulation.
Disables 2100 Hz answer tone to allow two
V.42 modems to connect more quickly.
4
5
6
16
32
64
Enables V.23 fallback mode.
Disables V.32bis mode.
Reserved
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (17 of 21) [2/7/2000 10:55:44 AM]
RMM Rack Mount Modem; User's Guide
7
128
Software compatibility code. This setting
disables the codes and displays the 9600
code instead. The actual rate of the call can
be viewed on the ATI6 screen. Used for
unusual software incompatibilities. Some
software may not accept 7200, 12000 and
14400 bps or greater result codes.
S28
0
8
Eliminates the V.32 answer tones for a faster connection.
Default item, all times are in tenths of a second.
Disables all connections except V.32 at 9600 bps.
Sets the duration (in tenths of a second) of the V.21 answer mode.
Reserved
255
20
0
S29
S30
S31
S32
128
2
Reserved
Bit-mapped register setup for 28.8 modems only. To set the register,
see the instructions for S13.
Bit
0
Value
Result
1
Enable V.8 Call Indicate.
Enable V.8 mode.
Disable V.34 modulation.
Disable 33.6 Kbps support.
Reserved
1
2
8
3
4
16
5 - 7
32 - 128
S33
0
Bit-mapped register setup for 28.8 modems only. To set the register,
see the instructions for S13.
Bit
0
Value
1
Result
Disable 2400 symbol rate.
Disable 2743 symbol rate.
Disable 2800 symbol rate.
Disable 3000 symbol rate.
Disable 3200 symbol rate.
Disable 3429 rate.
1
2
2
4
3
8
4
16
32
64
128
5
6
Reserved
7
Disable shaping.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (18 of 21) [2/7/2000 10:55:45 AM]
RMM Rack Mount Modem; User's Guide
S34
0
Bit-mapped register setup for 28.8 modems only. To set registers, see
instructions for S13.
Bit
Value
1
Result
0
Disable 8S-2D trellis encoding.
Disable 16S-4D trellis encoding.
Disable 32S-2D trellis encoding.
Disable 64S-4D trellis encoding.
Disable nonlinear coding.
Disable TX level deviation.
Disable Pre-emphasis.
1
2
2
4
3
8
4
16
32
64
128
5
6
7
Disable Pre-coding.
S35 - S37
S38
---
0
Reserved
Sets an optional delay (in seconds) before a forced hang-up and
clearing of the Transmit buffer when DTR drops during an ARQ call.
This allows time for a remote modem to acknowledge receipt of all
transmitted data before it is disconnected.
When set at the default (0), the modem immediately hangs up when
DTR drops.
This option applies only to connections terminated by dropping DTR.
If the modem receives the ATH command, it ignores S38 and
immediately hangs up.
7. Specifications
Compatibility:
ITU-T V.34+: 33.6 Kbps
ITU-T V.34: 28.8 Kbps
ITU-T V.32 bis: 14.4 Kbps
ITU-T V.32: 9600 bps
ITU-T V.22 bis: 2400 bps
Bell: 212 / V.22, 103 / V.21
Supports: V.42 / MNP 2-4 Error Control V.42 bis / MNP 5 Data Compression.
Command Set: Industry Standard "AT" Commands
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (19 of 21) [2/7/2000 10:55:45 AM]
RMM Rack Mount Modem; User's Guide
Status/Help: Status display shows current settings and stored numbers. A Help display summarizes the
command set and S-Register functions.
FCC Reg. No.: CJEUSA-24375-M5-E
Ringer Equivalence: 0.9 B
Compliance: FCC Part 68 / Part 15 Class B
Temperature: 0 degrees to 50 degrees C (operating)
Power:
AC Model: 115/230 VAC, 50/60 Hz, 10 Watts (switchable)
DC Model: 40 - 60 VDC, 10 Watts Maximum
Size: 1.75" x 19.00" x 4.5" (H x W x D)
Weight: 4 pounds shipping weight
8. Customer Service
Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When calling,
please be prepared to give the name and make of the unit, its serial number and a description of its
symptoms. If the unit should need to be returned for factory repair it must be accompanied by a Return
Authorization number from Customer Service.
WTI Customer Service
5 Sterling
Irvine, California 92618
U.S. and Canada: 1-800-854-7226
Phone: 949-586-9950
Fax: 949-583-9514
Email: [email protected]
Trademark and Copyright Information
WTI and Western Telematic are trademarks of Western Telematic, Inc. All other product names
mentioned in this publication are trademarks or registered trademarks of their respective companies.
Information and descriptions contained herein are the property of Western Telematic, Inc. Such
information and descriptions may not be copied disseminated or distributed without the express written
consent of Western Telematic, Inc.
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (20 of 21) [2/7/2000 10:55:45 AM]
RMM Rack Mount Modem; User's Guide
© Copyright Western Telematic, Inc. 1998
Printed in the United States of America
January 2000
Part Number: 12548 Revision: F
file:///C|/WEBPAGE/guides/rmm/rmm_manl.htm (21 of 21) [2/7/2000 10:55:45 AM]
|