GAS HOBS
ZGL 62
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
GB
Contents
For the User
For the Installer
Engineers technical data
Installation
9
10
10
11
12
13
13
15
15
Important Safety Information
Description of the Hob
Operation
2
3
4
4
5
5
6
6
Important Safety Requirements
Building In
Maintenance and Cleaning
Something Not Working?
Service and Spare Parts
Customer Care Department
Guarantee Conditions
Electrical connections
Wiring Diagram
Fault Finding
Commissioning
Conversion from Natural Gas to LPG
Description of the Hob
3
3
2
1
5
4
6
1. Hob Top
2. Rapid Burner
3. Semi-rapid Burners
4. Auxiliary Burner
5. Control knobs
6. Electric Ignition Push Button
3
Operation
Hob Burners
To light a burner:
turn the relevant control knob anticlockwise to
maximum position;
atthesametimepushtheelectricignitionpushbutton
which is marked by a little spark;
then adjust the flame as required.
If you use a saucepan which is smaller than the
recommended size, the flame will spread beyond
the bottom of the vessel, causing the handle to
overheat.
F
l
l
l
As soon as a liquid starts boiling, turn down the
flame so that it will barely keep the liquid
simmering.
If the burner does not ignite, turn the control knob to
zero, and try again.
To ensure maximum burner efficiency, you should only
use pots and pans with a flat bottom fitting the size of
the burner used (see table).
Take care when frying food in hot oil or fat, as
the overheated splashes could easily ignite.
Burner
minimum
diameter
maximum
diameter
If the control knobs become difficult to turn, please
contact your local Zanussi Service Centre.
Large(rapid)
Medium(semi-rapid)
Small (Auxiliary)
180 mm.
120 mm.
80 mm.
260 mm.
220 mm.
160 mm.
Maintenance and Cleaning
Before any maintenance or cleaning can be carried
out, you must DISCONNECT the hob from the
electricity supply.
The hob is best cleaned whilst it is still warm, as
spillage can be removed more easily than if it is
left to cool.
The Hob Top
Regularly wipe over the hob top using a soft cloth well
wrungoutinwarmwatertowhichalittlewashingupliquid
has been added. Avoid the use of the following:
-householddetergentandbleaches;
- impregnated pads unsuitable for non-stick saucepans;
- steel wool pads;
- bath/sink stain removers.
Should the hob top become heavily soiled, it is
recommendedthatacleaningproductsuchasHobBrite
or Bar Keepers Friend is used.
Pan Supports
Thepansupportsaredishwasherproof. Ifwashingthem
by hand, take care when drying them as the enamelling
process occasionally leaves rough edges. If necessay,
remove stubborn stains using a paste cleaner.
The Burners
Theburnercapsandcrownscanberemovedforcleaning.
Washtheburnercapsandcrownsusinghotsoapywater,
and remove marks with a mild paste cleaner. A well
moistenedsoapimpregnatedsteelwoolpadcanbeused
with caution, if the marks are particularly difficult to
remove.
After cleaning, be sure to wipe dry with a soft cloth.
4
Something Not Working?
If the hob is not working correctly, please carry out the following checks before contacting your local Service Force
Centre.
IMPORTANT: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or
installation, a charge will be made even if the appliance is under guarantee.
SYMPTOM
SOLUTION
n There is no spark when lighting the gas
u Check that the unit is plugged in and the electrical
supply is switched on
u Check that the RCCB has not tripped (if fitted)
u Check the mains fuse has not blown
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
n The gas ring burns unevenly
u Check the main jet is not blocked and the burner
crown is clear of food particles.
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
If after all these checks, your hob still does not operate
correctly, contact your local Service Force Centre.
In-guarantee customers should ensure that the
above checks have been made as the engineer will
make a charge if the fault is not a mechanical or
electrical breakdown.
Please note that it will be necessary to provide proof of
purchase for any in-guarantee service calls.
Service and Spare Parts
In the event of your appliance requiring service, or if you
wish to purchase spare parts, please contact your local
Zanussi Service Force Centre by telephoning:
0870 5 929929
Your telephone call will be automatically routed to the
Service Force Centre covering your post code area. The
addresses are listed on the following pages.
Before calling out an engineer, please ensure you have
read the details under the heading Something Not
Working.
When you contact the Service Force Centre you will need
to give the following details:
1. Your name, address and post code
2. Your telephone number
3. Clear and concise details of the fault
4. The model and serial number of the appliance (found
on the rating plate)
5. The purchase date
5
Customer Care Department
For general enquiries concerning your Zanussi appliance
or for further information on Zanussi products, please
contact our Customer Care Department by letter or
telephone at the address below or visit our website at
Customer Care Department
Zanussi
55-77 High Street
Slough
Berkshire
SL1 1DZ
08705 727727 (*)
* calls to this number may be recorded for training
purposes.
Guarantee Conditions
Zanussi Guarantee conditions
*
Appliances found to be in use within a commercial
or similar environment, plus those which are the
subject to rental agreements.
Products of Zanussi manufacture which are not
marketed by Zanussi.
We, Zanussi, undertake that if, within 24 months of the
date of the purchase, this Zanussi appliance or any part
thereof is proved to be defective by any reason only of
faulty workmanship or materials, we will, at our option,
repair or replace the same FREE OFANY CHARGE for
labour, materials or carriage on condition that:
*
European Guarantee
If you should move to another country within Europe then
your guarantee moves with you to your new home
subject to the following qualifications:
*
*
*
The appliance has been correctly installed and used
only on the gas and electricity supply stated on the
rating plate.
The appliance has been used for normal domestic
purpose only, and in accordance with the
manufacturer's instructions.
The appliance has not been serviced, maintained,
repaired, taken apart or tampered with by any person
not authorised by us.
*
The guarantee starts from the date you first
purchased your product.
*
The guarantee is for the same period and to the same
extent for labour and parts as exist in the new country
of use for this brand or range of products.
This guarantee relates to you and cannot be
transferred to another user.
Your new home is within the European Community
(EC) or European Free Trade Area.
The product is installed and used in accordance with
our instructions and is only used domestically, i.e. a
normal household
*
*
*
*
*
*
All service work under this guarantee must be
undertaken by a Zanussi Service Centre.
Any appliance or defective part replaced shall
become the Company's property.
This guarantee is in addition to your statutory and
other legal rights.
*
The product is installed taking into account
regulations in your new country.
Home visits are made between 8.30am and 5.30pm
Monday to Friday. Visits may be available outside these
hours, in which case a premium will be charged.
Before you move, please contact your nearest Customer
Care centre, listed below, to give them details of your
new home. They will then ensure that the local Service
Organisation is aware of your move and able to look after
you and your appliances.
Exclusions
This guarantee does not cover:
*
Damage or calls resulting from transportation,
improper use or neglect, the replacement of any light
bulbs or removable parts of glass or plastic.
Costs incurred for calls to put right an appliance
which is improperly installed or calls to appliance
outside the United Kingdom.
France
Germany
Italy
Sweden
UK
Senlis
Nürnberg
+33 (0)3 44 62 29 99
+49 (0)911 323 2600
Pordenone +39 (0)1678 47053
Stockholm +46 (0)8 738 79 50
*
Slough
+44 (0)1753 219897
6
ZANUSSI SERVICE FORCE
To contact your local Zanussi Service Force Centre telephone 08705 929 929
NORTH EAST
CHANNEL ISLANDS
ORKNEY
(M65)
Corsie Domestics
7 King Street
Kirkwall
GATESHEAD
(M39)
Unit 356a
Dukesway Court
Dukesway
Team Valley
GUERNSEY
JERSEY
Guernsey Electricity
PO Box 4
Vale, Guernsey
Channel Islands
Orkney KW15
PERTH
PERTH
Hydro Electrical
Gateshead NE11 0BH
Inveralmond House
Ruthervenfield Road
Perth PH1 3AQ
Jersey Electricity Company
PO Box 45
Queens Road
St Helier
Jersey
GRIMSBY
(M42)
15 Hainton Avenue
Grimsby
South Humberside
DN32 9AS
Graham Begg
Unit 4
Airport Ind Estate
Wick KW1 4QS
Channel Islands JE4 8NY
HULL
(M41)
Unit 1
Boulevard Industrial
Estate
Hull
HU3 4AY
(OWN SALES)
SHETLAND
Tait Electronic Systems Ltd
Holmsgarth Road
Lerwick
SCOTLAND
ABERDEEN
(M05)
54 Claremont Street
Aberdeen AB10 6RA
(OWN SALES)
SHETLAND
Shetland ZE1 0PW
LEEDS
(M37)
64-66 Cross Gates Road
Leeds
LS15 7NN
Bolts Shetland Ltd.
26 North Road
Lerwick
AUCHTERMUCHY
(M03)
33a Burnside
Auchtermuchy
Fife KY14 7AJ
NEWTON AYCLIFFE Unit 16
(OWN SALES)
WHALSAY
Shetland ZE1 0PE
(M45)
Gurney Way
Aycliffe Industrial Estate
Newton Aycliffe
DL5 6UJ
BLANTYRE
(M07)
Unit 5
Block 2
Auchenraith Ind. Estate
Rosendale Way
Blantyre G72 0NJ
Leask Electrical
Harisdale
Symbister, Whalsay
(OWN SALES)
Shetland ZE2 9AA
SHEFFIELD
(M38)
Pennine House
Roman Ridge Ind.
Roman Ridge Road
DUMFRIES
(M01)
93 Irish Street
Dumfries
NORTHERNIRELAND
Sheffield
S9 1GB
Scotland DG1 2 PQ
BELFAST
(M27)
Owenmore House
Kilwee Business Park
Upper Dunmury Lane
Belfast
DUNOON
(M67)
Brair Hill
7 Hill Street
Dunoon
NORTH WEST
BT17 0HD
BIRKENHEAD
(M11)
1 Kelvin Park
Dock Road
Birkenhead
L41 1LT
Argyll PA23 7AL
GLASGOW
(M04)
20 Cunningham Road
Clyde Estate
Rutherglen
WALES
CARLISLE
(M10)
Unit 7
Glasgow G73 1PP
CARDIFF
(M28)
Guardian Industrial Estate
Clydesmuir Road
Tremorfa
Cardiff
CF2 2QS
James Street Workshops
James Street
Carlisle
INVERNESS
(M06)
Unit 3B
Smithton Ind. Estate
Smithton
Cumbria
CA2 5AH
Inverness IV1 AJ
ISLE OF MAN
(M64)
South Quay Ind. Estate
Douglas
Isle of Man
CLYWD
(M14)
Unit 6-7 Coed Parc
Abergele Road
Rhuddlan
ISLE OF ARRAN
Arran Domestics
Unit 4 The Douglas Centre
Brodick
IM1 5AT
Clwyd
(OWN SALES)
Isle of Arran KA27 8AJ
Wales
LL18 5UG
LIVERPOOL
(M15)
Unit 1
Honeys Green Precinct
Honeys Green Lane
Liverpool
ISLE OF BARRA
J Zerfah
244 Bruernish
Isle of Barra
DYFED
(M77)
Maes YCoed
High Mead
Llanybydder
Carmarthenshire
SA40 9UL
L12 9JH
(OWN SALES)
Western Islands HS9 5QY
MANCHESTER
(M09)
Unit B
ISLES OF BUTE
(M66)
Walker Engineering
Glenmhor
Upper Serpentine Road
Rothesay
Central Industrial Estate
St Marks Street
Bolton
HAVERFORDWEST Cromlech Lodge
(M75)
Ambleston
Haverfordwest
BL3 6NR
Isle of Bute PA20 9EH
Pembrokeshire
SA62 5DS
PRESTON
(M13)
Unit 250
ISLE OF LEWIS
(M69)
ND Macleod
16 James Street
Stornoway
Dawson Place
Walton Summit
Bamber Bridge
Preston
OSWESTRY
(M17)
Plas Ffynnon
Warehouse
Middleton Road
Oswestry
Isle of Lewis PA87 2QW
Lancashire PR5 8AL
KELSO
(M08)
2-8 Wood Market
Kelso
Borders TD5 7AX
SY11 2PP
STOCKPORT
(M16)
Unit 20 Haigh Park
Haigh Avenue
Stockport
SK4 1QR
7
ZANUSSI SERVICE FORCE
To contact your local Zanussi Service Force Centre telephone 08705 929 929
MIDLANDS
LONDON & EASTANGLIA
SUNBURY
(M63)
Unit 1a
The Summit
BIRMINGHAM
(M18)
66 Birch Road East
Wyrley Road Ind. Estate
Witton
Birmingham
B6 6DB
Hanworth Road
Hanworth Ind. Estate
Sunbury on Thames
TW16 5D
BECKENHAM
(M79)
11a Gardener Ind. Estate
Kent House Lane
Beckenham
Kent BR3 1QZ
CHELMSFORD
(M47)
Hanbury Road
Widford Ind. Estate
Chelmsford
Essex
BOURNE
(M44)
Manning Road Ind.
Estate
Pinfold Road
Bourne
SOUTH EAST
ASHFORD
(M58)
Unit 2
CM12 3AE
Bridge Road Business Est.
Bridge Road
Ashford
PE10 9HT
COLINDALE
(M53)
Unit 14
BRIDGNORTH
(M72)
68 St. Marys Street
Bridgnorth
Shropshire
Capitol Park
Capitol Way
Colindale
Kent TN2 1BB
FLEET
(M59)
Unit 1
WV16 4DR
London NW9 0EQ
Redsfield Ind. Estate
Church Crookham
Fleet
GLOUCESTER
(M23)
101 Rycroft Street
Gloucester
GL1 4NB
ELTHAM
(M78)
194 Court Road
Mottingham
Eltham
Hampshire GU13 0RD
London SE9 4EW
HAYWARDS
HEATH
(M55)
21-25 Bridge Road
Haywards Heath
Sussex RH16 1UA
HEREFORD
(M31)
Unit 3
Bank Buildings
Cattle market
Hareford
ENFIELD
(M49)
284 Alma Road
Enfield
London
HE4 9HX
EN3 7BB
SOUTH WEST
HIGHAM FERRERS 30 High Street
GRAVESEND
(M57)
Unit B4
BARNSTAPLE
(M30)
Main Road
Fremington
Barnstaple
North Devon EX31 2NT
(M51)
Higham Ferrers
Northants
Imperial Business Estate
Gravesend
Kent
NN10 8BB
DA11 0DL
ILKESTON
(M43)
Unit 2
Furnace Road
Ilkeston DE7 5EP
BOURNEMOUTH 63-65 Curzon Road
(M26)
HARPENDEN
(M46)
Unit 4
Bournemouth
Dorset
BH1 4PW
Riverside Estate
Coldharbour Lane
Harpenden
AL5 4UN
LEICESTER
(M22)
Unit 7
Oaks Ind. Estate
Coventry Road
Narborough
Leicestershire
LE0 5GF
BRIDGEWATER
(M35)
6 Hamp Ind. Estate
Bridgewater
Somerset TA6 3NT
LETCHWORTH
(M50)
16-17 Woodside Ind. Estate
Works Road
Letchworth
Herts
SG6 1LA
BRISTOL
(M25)
11 Eldon Way
Eldonwall Trading
Bristol
LINCOLN
Unit 8
(M40)
Stonefield Park
Clifton Street
Lincoln
Avon BS4 3QQ
LONDON
(M76)
2/4 Royal Lane
Yiewsley
West Drayton
Middlesex
EMSWORTH
(M33)
266 Main Road
Southbourne
Emsworth
LN5 8AA
NEWCASTLE
UNDER LYME
(M12)
18-21 Croft Road
Brampton Ind. Estate
Newcastle under Lyme
Staffordshire
UB7 8DL
PO10 8JL
MAIDENHEAD
(M60)
Reform Road
Maidenhead
Berkshire
ISLE OF WIGHT
(M34)
Unit 8
Enterprise Court
Ryde Business Park
Ryde
ST5 0TW
SL6 8BY
Isle of Wight PO33 1DB
REDDITCH
(M20)
13 Thornhill Road
North Moons Moat
Redditch
Worcestershire
B98 9ND
MOLESEY
(M61)
10 Island Farm Avenue
West Molesey
Surrey
NEWTONABBOT Unit 2
(M29)
Zealley Ind. Estate
KT8 2UZ
Kingsteignton
Newton Abbot
S. Devon
NEWBURY
(M24)
9 Pipers Court
Berkshire Drive
Thatcham
Berkshire
RG19 4ER
TAMWORTH
(M19)
Unit 3
TQ12 3TD
Sterling Park
Claymore
Tamworth
B77 5DO
REDRUTH
(M36)
Unit 7D
Pool Ind. Estate
Wilson Way
Redruth
IPSWICH
(M48)
Unit 6C
WORCESTER
(M73)
Units 1 & 2
Elton Park Business Centre
Hadleigh Road
Ipswich
Cornwall TR15 3QW
Northbrook Close
Gregorys Mill Ind. Estate
Worcester
IP2 0DD
WR3 8BP
NORWICH
(M52)
2b Trafalgar Street
Norwich
NR1 3HN
8
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
SUPPLY CONNECTIONS
Gas:
Width:
Depth:
580 mm.
500 mm.
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
CUT OUT DIMENSIONS
Width:
Depth:
550 mm.
470 mm.
Thickness: 30 mm.
Ignition HT Spark
Spark Generator
Spark Gap
Ispra Control's BF 50066 - 230-240V 0.6 YA T 120
Fixed
Rear Right Burner (semi-rapid)
Rear Left Burner (semi-rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Heat Input
2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input
Front Left Burner (rapid)
Heat Input
1.0 kW (3412 BTU/HR)
3.0 kW (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
BURNER
RAPID
(large)
SEMI-RAPID
(medium)
AUXILIARY
(small)
Characteristics
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
kW
3.0
0.65
2.0
0.190
9 6
0.45
0.038
Adjust.
1.0
0.095
7 0
0.33
0.028
Adjust.
m3/h
0.286 0.057
NOZZLE REFERENCE
1/100 mm
119
2.8
Adjust.
0.65
NOMINAL THERMAL
POWER
kW
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE
g/h
202
8 6
43.5
4 0
144
7 1
2 9
3 2
7 2
5 0
21.5
2 8
NOZZLE REFERENCE
1/100 mm
Burner
Dia. Tap By-pass
1/100 mm
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
Auxiliary
28
Semi-rapid32
Rapid40
Aerationadjustmentnone
APPLIANCE GAS SUPPLY:
Natural gas G20 / 20mbar
9
Important safety requirements
FITTING THE GAS HOB
WITHOUTACOOKERHOODABOVE
This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current Edition)
and the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in the following
British Standards Codes Of Practice: B.S. 6172/ B.S.
5440, Part 2 and B.S. 6891 Current Editions.
700 mm
The hob should not be installed in a bed sitting room
with a volume of less than 20 m3. If it is installed in a
room of volume less than 5 m3 an air vent of effective
area of 110 cm2 is required. If it is installed in a room of
volume between 5 m3 and 10 m3 an air vent of effective
area of 50 cm2 is required, while if the volume exceeds
11 m3 no air vent is required.
400 mm
55 mm
400 mm
100 mm
50 mm
However, if the room has a door which opens directly to
the outside no air vent is required even if the volume is
between 5 m3 and 11 m3.
If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent requirements.
FO 0812
FITTING THE GAS HOB
WITHACOOKERHOODABOVE
600 mm
Location
The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom, shower room or
garage.
650 mm
Before making the cut out in the worktop ensure that the
edges of the hob that are to be near either a side or rear
wall have a minimum distance of 55 mm. between the
edge of the hob and the wall.
The minimum distance combustible material can be fitted
above the hob is 400 mm. If it is fitted below 400 mm. a
space of 50 mm. must be allowed from the edges of the
hob.
400 mm
55 mm
50 mm
400 mm
100 mm
50 mm
The minimum distance combustible material can be fitted
directly above the hob is 700 mm.
A minimum distance of 100 mm. must be left between
the side edges of the hob and any adjacent cabinets or
walls.
FO 0813
Installation
IMPORTANT
WHEN THE HOB IS FIRST INSTALLED
This hob must be installed by qualified
personnel to the relevant British Standards.
Once the hob has been installed, it is important
to remove any protective materials, which were
put on in the factory.
Any gas installation must be carried out by a
registered CORGI installer.
On the end of the shaft, which includes the GJ 1/2"
threaded elbow, adjustment is fixed so that the washer
is fitted between the components as shown in the
diagram. Screw the parts together without using excessive
force.
The manufacturer will not accept liability, should
the above instructions or any of the other safety
instructions incorporated in this book be
ignored.
10
Gas Connection
Connection to the gas supply should be with either rigid
or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to RC
1/2 (1/2 BSP male thread).
When the final connection has been made, it is essential
that a thorough leak test is carried out on the hob and
installation.
Ensure that the main connection pipe does not exert
any strain on the hob.
A) End of shaft with nut
B) Washer
C) Elbow
FO 0264
Rectangular cut-out size for hob
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to the
hob connecting pipe.
Failure to ensure the correct assembly will cause
leakage of gas.
55 min.
Cut Out Size
The dimensions of the cut-out are given in the diagram.
470
550
Dimensions are given in mm.
FO 2098
1
ON/OFF SWITCH
Building In
Building over a cupboard or
drawer
FLEX
OUTLET
If the hob is to be installed above a cupboard or drawer
it will be necessary to fit a heat resistant board below
the base of the hob on the underside of the work
surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.
FO 0763
Building over a kitchen unit
with door
ON/OFF SWITCH
3
2
Proper arrangements must be taken in designing the
furniture unit, in order to avoid any contact with the
bottom of the hob which can be heated when it is
operated. The recommended solution is shown in
diagram 3.
The panel fitted under the hob ("a") should be easily
removable to allow easy access if technical
assistance is needed. The space behind the kitchen
unit ("b") can be used for connections.
a
60
b
FLEX
OUTLET
FO 1013
FO 0764
Dimensions are given in mm.
11
Fitting the Hob into the worktop
Carry out the building in of the hob as follows:
put the seals supplied with the hob, on the
edges of the cut out: place them exactly on
the front and rear edge and at 50 mm. from the
side edges, taking care that the seals meet
without overlapping;
F
a
place the hob in the cut out, taking care that it
is centred;
fix the hob with the relevant fixing clamps and
screws, as shown in the diagram. When the
screws have been tightened, the excess seal
can be removed.
FO 0199
a) Sealing gasket
The edge of the hob forms a double seal which prevents
the ingress of liquids.
Electrical connections
Any electrical work required to install this hob
should be carried out by a qualified electrician or
competent person, in accordance with the current
regulations.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
A cut off plug inserted into a 13 amp socket is
a seriuos safety (shock) hazard. Ensure that
the cut off plug is disposed of safely.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these
safety measures not be observed.
This hob is designed to be connected to a 230-240V
50Hz AC electrical supply.
Permanent Connection
In the case of a permanent connection, it is necessary
that you install a double pole switch between the hob
and the electricity supply (mains), with a minimum gap
of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the current
electric regulations.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord
incorporating a 3amp plug fitted. In the event of having to
change the fuse, a 3ampASTAapproved (BS 1362) fuse
must be used.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not come
into contact with surfaces with temperatures
higher than 50 deg. C.
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow - Earth
Blue
- Neutral
-Live
Brown
Connect the green and yellow (earth) wire to
the terminal in the plug which is marked with
F
the letter 'E' or the earth symbol
green and yellow.
or coloured
Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N' or
coloured black.
Connect the brown (live) wire to the terminal in
the plug which is marked with the letter 'L' or
coloured red.
FO 0390
12
Wiring Diagram
L
1
A
2
3
4
5
6
0
220/240
A. IGNITOR SWITCH
B. IGNITOR UNIT
B
N
Fault Finding
Preliminary Electrical Systems
Check
SOCKET
(face view)
PLUG (with cover
removed)
( )
Earth Wire
Green/Yellow
( )
E
Blue
Brown
Green
Yellow
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
Neutral Wire
Blue
N
L
Blue
Green
Yellow
Brown
Carry out:
D: Resistance to
Earth check.
Electricity supply
should now be
satisfactory.
NO
YES
Carry out:
C: Polarity check.
Has inlet fuse blown?
A. EARTH CONTINUITY CHECK -Appliance must be
electrically disconnected - meter set on W (Ohms) x
1 scale and adjust zero if necessary.
NO
YES
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than 0.1
ý (Ohm), check all earth wires for continuity and
all contacts are clean and tight.
Inlet wiring
faulty.
B. INSULATION CHECK - Appliance electrically
Rectify any
fault.
disconnected, all switches ON.
a) meter set on W(Ohms) x 1 scale.
Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.
b) meter set on W (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than × (infinity) there is a fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.
13
Ignition System / Gas Ignition
YES
Check gas supply at
burner
Ignitor does not spark
NO
Check plug top fuse
and replace if
necessary
Light burner manually
Check polarity and
earth continuity of
supply point
Check by pass simmer
adjusted
Check position of the
electrode
Check earth continuity
of appliance
Check continuity from the tip of
each electrode to the
terminals 1 to 4 on the ignitor
unit
Check fitting of burners
Check continuity from 'N' on the
mains connector block and "O" on
the ignitor unit
Check continuity from 'L' on the
mains connector block and the
taps ignition switches
Check for breaks in the
insulation
of the HT leads
Check continuity from ignition
switches connector to ignitor unit
Change the taps
ignition switches
Change the ignitor unit
14
Commissioning
When the hob has been fully installed it will be necessary
to check the minimum flame setting. To do this, follow
the procedure below.
-
-
Turn the gas tap to the MAX position and ignite.
Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Minimum adjustment screw
FRemove the control knob.
To adjust, use a thin bladed screwdriver and turn
the adjustment screw (see diagram) until the flame
is steady and does not extinguish, when the knob
is turned from MIN to MAX. Repeat this procedure
for all burners.
Pressure Testing
Remove left hand pan support and front left burner
Fcap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite another
burner.
The pressure reading should be nominally 20mbar
and must be between 17 mbar and 25mbar.
Turn off the burner supplies.
Conversion from Natural Gas to LPG
It is important to note that this model is designed for use
To adjust the gas rate
with natural gas but can be converted for use with butane
With the aid of a thin bladed screwdriver completely
or propane gas providing the correct injectors are fitted.
tighten down the by pass adjustment screw, which is
The gas rate is adjusted to suit.
located down the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate on
the under side of the hob.
Method
Ensure that the gas taps are in the 'OFF' position
IMPORTANT
Isolate the hob from the electrical supply
Remove all pan supports, burner caps, rings, crowns
and control knobs.
With the aid of a 7mm box spanner the burner injectors
can then be unscrewed and replaced by the
appropriate LPG injectors.
The replacement/conversion of the gas hob should only
be undertaken by a competent person.
15
CUSTOMER CARE
Zanussi
55-77 High Street
Slough
Berkshire, SL1 1DZ
Tel: 08705-727727
© Electrolux HouseholdAppliances Limited 2000
From the Electrolux Group. The worlds No.1 choice.
The Electrolux Group is the worlds largest producer of powered appliances for kitchen, cleaning and outdoor use. More than
55 Group products (such as refrigerators, cookers, washing machines, vacuum cleaners, chain saws and lawn mowers) are
sold each year to a value of approx. USD 14 billion in more than 150 countries around the world.
35675-2601
09/00
|